Fire Hooter And MCP
Fire Hooter And MCP

Fire Hooter And MCP

MOQ : 1 Piece

Fire Hooter And MCP Specification

  • Coating Type
  • Fire retardant ABS plastic
  • Mounting Type
  • Surface Mount
  • Fire Class
  • Not Applicable (Detection device, not an extinguisher)
  • Control Type
  • Manual activation (MCP) / Automatic by Fire alarm panel
  • Coverage Area
  • Depends on system design, typically up to 25 meters for sounder
  • Connectivity Type
  • Wired connection to fire alarm control panel
  • Features
  • High-intensity sounder, Visual LED indicator, Easy reset mechanism, Durable ABS body, Quick response time
  • Voltage
  • 24V DC (standard for fire alarm sounders/MCP)
  • Working Temperature
  • -10C to +55C (typical for MCP and sounder units)
  • Shape
  • Rectangular
  • Technology
  • Electronic sounder and manual call point (MCP)
  • Installation Type
  • Wall-mounted
  • Application
  • Fire alarm systems, Commercial buildings, Residential complexes, Industrial sites
  • Dimensions
  • Approx. 100mm x 100mm x 50mm (individual units)
  • Material
  • Polycarbonate/ABS plastic housing
  • Reset Method
  • Manual reset using key or tool
  • Alarm Type
  • Audible and Visual (Sounder with LED)
  • Ingress Protection
  • IP 44 (typical for indoor units)
  • Sound Output Level
  • 90-110 dB at 1 meter
  • Operating Current
  • <100 mA (at 24V DC)
  • Response Time
  • <1 second activation
  • Color
  • Red
 

Fire Hooter And MCP Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 2-5 Days
  • Main Domestic Market
  • All India
 

Fire Hooter And MCP About



Introducing our Advance Purchase Fire Hooter and MCP set, a trending best-seller in fire safety solutions. Engineered with a formidable sound output of 90-110 dB and visible LED alert, this gilt-edged device guarantees rapid notification within 1 second of activation. The preeminent polycarbonate/ABS housing provides both durability and fire resistance, while the device's easy manual reset and IP44 protection make it ideal for diverse indoor applications. Secure this essential alarm system for commercial buildings, industrial sites, and residential complexes-trusted by top service providers and suppliers across India.

Commercial Utility, Application Versatility, and Competitive Advantages

The Fire Hooter and MCP are expertly designed for formidable performance in commercial buildings, industrial facilities, and residential complexes. With easy wall-mounted installation on most indoor surfaces and robust IP44 ingress protection, it adapts seamlessly to varied application areas. Its durable ABS housing, quick activation under a second, and high-intensity visual and audible alerts provide a preeminent edge over standard units, ensuring advanced and reliable fire alert coverage for up to 25 meters.


Sample Policy, Shipping Safety, and Packaging Information

Samples for Fire Hooter and MCP can be requested via quotation, enabling buyers to evaluate the product before placing bulk orders. Orders are dispatched from our FOB port in secure, industry-compliant packaging that safeguards each unit during transit. Our policy ensures all shipments are handled with care, and buyers benefit from reliable, secure shipping-with timely updates provided until the product arrives at your preferred location.


FAQ's of Fire Hooter And MCP:


Q: How is the Fire Hooter and MCP installed in commercial buildings?

A: The Fire Hooter and MCP are designed for wall-mounted, surface installation, allowing easy integration into most commercial and industrial indoor environments using wired connections to the building's fire alarm control panel.

Q: What makes this Fire Hooter and MCP a best-selling fire notification unit?

A: Its gilt-edged features, such as high-intensity sound (90-110 dB), durable ABS/polycarbonate body, quick manual or automatic activation, and clear visual LED lights, combine to deliver preeminent performance, making it a trending and dependable choice.

Q: Where is the optimal location for mounting this fire alarm system?

A: Install units in high-traffic areas, corridors, and near exits within the recommended 25-meter coverage to maximize notification reach and ensure prompt evacuation during fire emergencies.

Q: What is the process for resetting the MCP after an alarm activation?

A: After activation, the MCP is manually reset using a dedicated key or tool included with the unit-ensuring security and controlled access to re-arm the alarm after addressing the incident.

Q: What benefits does the IP44 ingress protection offer?

A: IP44 ingress protection shields the unit from splashes and dust commonly present in indoor environments, relying on formidable build quality for durable operation in various commercial and residential settings.

Q: How quickly does the Fire Hooter respond to a fire alarm signal?

A: The sounder and LED indicator activate within less than one second of receiving a trigger, delivering immediate notification to occupants and significantly improving safety response times.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Fighting Equipments Category

Tyco Fire Sprinklers

Tyco Fire Sprinklers

Minimum Order Quantity : 1 Piece

Features : Corrosionresistant, Fast Response, Heat Sensitive

Control Type : Automatic

Coverage Area : 1216 sq. m (Standard coverage dependent on model)

Connectivity Type : Mechanical Threaded Connection

Application : Fire Protection Systems

ABC Fire Extinguisher Valve

ABC Fire Extinguisher Valve

Minimum Order Quantity : 1 Piece

Features : Pressure Gauge, Easy Recharging, Durable Metal Body, Smooth Lever Operation

Control Type : Lever

Coverage Area : Depends on the attached extinguisher cylinder

Connectivity Type : Mechanical Threaded Connection

Application : Used for ABC Type Fire Extinguishers

Double Door Fire Hose Box

Double Door Fire Hose Box

Minimum Order Quantity : 1 Piece

Features : Double door design, powder coated finish, wallmountable, robust steel construction, glass doors/windows

Control Type : Manual

Coverage Area : Depends on hose length, typically up to 30 meters

Connectivity Type : Fire hydrant system/manual hose connection

Application : Fire safety, emergency use in buildings, factories, warehouses, public areas

Safety Fire Bucket With Stand

Safety Fire Bucket With Stand

Minimum Order Quantity : 1 Piece

Features : Durable construction, corrosionresistant, visible red paint, labeled FIRE, easy to use and refill

Control Type : Manual

Coverage Area : Depends on accessible area around the bucket stand

Connectivity Type : Nonelectrical, standalone

Application : Used for emergency fire fighting and storing sand or water



Back to top