Sprinkler Alarm Valve
Sprinkler Alarm Valve

Sprinkler Alarm Valve

MOQ : 1 Piece

Sprinkler Alarm Valve Specification

  • Energy Efficiency Rating
  • Not applicable (mechanical device)
  • Coating Type
  • Red epoxy powder coated finish
  • Working Temperature
  • 4C to 70C continuous operation
  • Operating Pressure
  • 1.2 MPa (typical operating range)
  • Fire Extinguisher Type
  • Not applicable (Sprinkler system component)
  • Control Type
  • Mechanical (alarm activation), manual reset
  • Fire Class
  • Class A and B fires
  • Shape
  • Cylindrical and flanged body design
  • Mounting Type
  • Flange mounted to piping/floor bracket
  • Coverage Area
  • Designed as per sprinkler system layout
  • Connectivity Type
  • Mechanical connection to water supply and alarm system
  • Features
  • Corrosion resistant, Quick response, Audible alarm, Visible pressure gauges, Durable finish
  • Voltage
  • Not applicable (mechanical device)
  • Technology
  • Wet pipe alarm valve with mechanical and hydraulic alarm
  • Installation Type
  • Vertical floor mounting
  • Application
  • Automatic fire sprinkler system for fire safety
  • Max Flow Rate
  • Up to 450 L/min (model dependent)
  • Diameter
  • 100 mm (nominal, varies by model)
  • Capacity
  • System-dependent, see design specifications
  • Pressure
  • Rated for 12 bar (model dependent)
  • Color
  • Red (standard fire safety color)
  • Alarm Bell Size
  • 6''-8'' mechanical water motor gong
  • Inlet/Outlet Size
  • 100 mm inlet and outlet standard
  • Compliance Standards
  • IS 5290 / UL Listed / FM Approved (as specified per model)
  • Connection Standards
  • Flanged IS/ANSI/DIN
  • Maintenance Requirement
  • Periodic inspection and cleaning recommended
  • Alarm Activation
  • Hydraulic/mechanical when water flows
  • Test and Drain Valve
  • Provision for hydrostatic testing and drainage
  • Material
  • Cast iron body, brass trim, stainless steel internal parts
  • Operational Flow Direction
  • Upward (inlet below, outlet above)
 

Sprinkler Alarm Valve Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 2-5 Days
  • Main Domestic Market
  • All India
 

Sprinkler Alarm Valve About



Capitalise on the unwavering demand for top-drawer fire safety with our Sprinkler Alarm Valve-an essential for any modern facility. This noble component, boasting a pristine cast iron body with brass and stainless steel internals, delivers reliability where it matters most. Featuring a 100 mm flanged inlet/outlet, corrosion-resistant red epoxy finish, and mechanical/hydraulic alarm activation, it guarantees rapid response to Class A and B fires. Fully compliant with IS 5290, UL Listed, and FM Approved standards, this sale-worthy valve is engineered for vertical floor mounting in rigorous environments across India.

Reliable Fire Protection for Diverse Applications

Designed for application in commercial, industrial, and institutional spaces, the Sprinkler Alarm Valve is ideal for shopping malls, warehouses, hospitals, and high-rise buildings. Its upward flow and vertical mounting ease integration into automatic sprinkler systems. The method of application involves connecting it to the water supply and alarm bell system, providing real-time audible alerts upon fire detection. Suitable for large or small areas, its versatility enhances coverage for comprehensive fire safety.


Quick Quotes and Secure Shipment for Your Needs

Samples of the Sprinkler Alarm Valve are available upon request, supporting informed purchasing decisions. We offer competitive quotations tailored to your requirements. The products are securely packaged and shipped from FOB ports across India, ensuring pristine condition on arrival. Typical delivery time is prompt and managed to meet urgent project schedules. Trust our service provider status for secure shipping, timely delivery, and professional support from inquiry through to installation.


FAQ's of Sprinkler Alarm Valve:


Q: How does the Sprinkler Alarm Valve activate during a fire?

A: The valve activates hydraulically and mechanically when water flows due to a sprinkler head opening, triggering both an audible alarm (mechanical bell) and visual pressure indications.

Q: What are the installation and connection standards for this valve?

A: It features a 100 mm flanged inlet and outlet, compatible with IS, ANSI, and DIN standards, designed for vertical floor mounting in sprinkler systems.

Q: Where can this sprinkler alarm valve be used effectively?

A: It is suitable for commercial, industrial, and institutional buildings, including warehouses, offices, hospitals, and malls, ensuring wide-ranging fire safety.

Q: When should the Sprinkler Alarm Valve be inspected or maintained?

A: Periodic inspection and cleaning are recommended to ensure optimal operation, typically as part of routine fire system maintenance.

Q: What are the main benefits of this valve for fire safety?

A: It offers corrosion resistance, audible alarms, quick response, and compliance with top fire safety standards, ensuring high reliability and safety.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Fighting Equipments Category

Double Hydrant Valve

Double Hydrant Valve

Minimum Order Quantity : 1 Piece

Coating Type : Red Epoxy Powder Coated

Working Temperature : 5C to 80C

Shape : Y Shape (Double Outlet)

Mounting Type : Flanged Vertical Mount

Application : Fire fighting systems, water distribution in hydrant lines

SS Hidden Valve

SS Hidden Valve

Minimum Order Quantity : 1 Piece

Coating Type : Epoxy powder coating

Working Temperature : 10C to +80C

Shape : Cylindrical with round flange base

Mounting Type : Floor or wall flange mounted

Application : Firefighting systems, Hydrant systems, Industrial and commercial buildings

RRL Hose Pipe

RRL Hose Pipe

Minimum Order Quantity : 1 Piece

Coating Type : Rubber Lined

Working Temperature : 10C to +55C

Shape : Flat when not in use, becomes round when pressurized

Mounting Type : Portable / On Hose Reel

Application : Fire Fighting

Brass Forged Cap

Brass Forged Cap

Minimum Order Quantity : 1 Piece

Coating Type : Polished finish or nickel plating

Working Temperature : 10C to +120C

Shape : Round

Mounting Type : Threaded, male/female options

Application : Used for closing the ends of brass pipe fittings in plumbing, gas, and fire safety systems