Double Hydrant Valve
Double Hydrant Valve

Double Hydrant Valve

MOQ : 1 Piece

Double Hydrant Valve Specification

  • Mounting Type
  • Flanged Vertical Mount
  • Operating Pressure
  • Up to 16 bar
  • Shape
  • Y Shape (Double Outlet)
  • Technology
  • Conventional Mechanical Valve
  • Connectivity Type
  • Flanged Inlet, Instantaneous Outlet
  • Coating Type
  • Red Epoxy Powder Coated
  • Control Type
  • Manual, Wheel Operated
  • Fire Extinguisher Type
  • Hydrant Valve
  • Working Temperature
  • -5C to 80C
  • Installation Type
  • Surface Mounted (Vertical), Flange Mounting
  • Fire Class
  • A, B, C
  • Features
  • Corrosion Resistant, Dual Outlet, ISI Marked, Sturdy Construction
  • Coverage Area
  • Dependent on hose and nozzle, typically up to 25 meters radius
  • Application
  • Fire fighting systems, water distribution in hydrant lines
  • Max Flow Rate
  • 900 LPM (liters per minute)
  • Diameter
  • 63 mm (Standard)
  • Capacity
  • Double Outlet
  • Pressure
  • Up to 1.6 MPa (16 bar)
  • Handle Material
  • Aluminum/Brass (Wheel Type)
  • Weight
  • Approx. 7 to 10 kg
  • Inlet Connection
  • 100 mm Flanged
  • Compliance
  • IS 5290 Type B Standard
  • Protection
  • Dust Protection Cap with Chain
  • End Use
  • For Emergency Fire Water Supply Distribution
  • Color
  • Standard Red
  • Body Material
  • High Grade Gunmetal or Stainless Steel
  • Outlet Connection
  • 63 mm Female Instantaneous Coupling as per IS:903
 

Double Hydrant Valve Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 2-5 Days
  • Main Domestic Market
  • All India
 

Double Hydrant Valve About



Take advantage of a spectacular bargain with our Double Hydrant Valve, engineered for high-performance fire safety. Crafted from high-grade gunmetal or stainless steel, this valve features cost-effective longevity and is compliant with IS 5290 Type B Standard. Its dual-outlet Y shape delivers a soaring maximum flow rate of 900 LPM, perfect for emergency water distribution. Marvelous corrosion resistance, dust protection cap, and sturdy construction ensure reliability. Last chance for limited stock-trust in a valve built for protection, value, and efficiency in demanding fire-fighting environments.

Plant Applications & Suitability of Double Hydrant Valve

The Double Hydrant Valve is ideal for industrial plants requiring robust water distribution and fire-fighting infrastructure. Its spectacular design and corrosion-resistant features make it suitable for use in factories, warehouses, commercial complexes, and public buildings. The device is tailored for areas with high-risk fire classes (A, B, C), ensuring prompt emergency response. Its utilization in hydrant networks simplifies protection across vast areas, providing a dependable safety solution where comprehensive coverage is paramount.


Stock Ready: Payment, Packaging & Certification Details

Domestic markets can benefit from stock ready for quick dispatch. Accepted payment terms include advance payment and secure online transfers, ensuring a smooth transaction process. Products are packed with care in durable materials for express shipping across India. Each valve carries national certifications and ISI marking, verifying compliance with rigorous standards. Enjoy peace of mind with reliable packaging, certified quality, and swift delivery directly from reputed suppliers, traders, and service providers nationwide.


FAQ's of Double Hydrant Valve:


Q: How does the Double Hydrant Valve benefit fire-fighting systems in industrial settings?

A: The Double Hydrant Valve delivers rapid water supply with dual outlets, enabling effective fire-fighting and wide coverage, essential for industrial and plant applications.

Q: What is the process for installing this valve in a new hydrant line?

A: Installation involves flange mounting the valve on a vertical surface at the designated water distribution point. Follow IS:903 and IS 5290 standards for safety and compatibility.

Q: Where is the Double Hydrant Valve most suitable for use?

A: This hydrant valve is best suited for factories, warehouses, commercial buildings, and large-scale public spaces, especially those requiring emergency fire water distribution.

Q: When should the dust protection cap be used?

A: The dust protection cap should be secured at all times when the valve is not in active use, ensuring that debris and contaminants don't compromise performance.

Q: How is express shipping handled for urgent domestic orders?

A: Express shipping is available for stock-ready models, ensuring swift dispatch and delivery to domestic locations across India through partnered logistics services.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Fighting Equipments Category

Double Door Fire Hose Box

Double Door Fire Hose Box

Minimum Order Quantity : 1 Piece

Working Temperature : 10C to +55C (cabinet material and components dependent)

Installation Type : Wall mounted (surface or recessed options available)

Features : Double door design, powder coated finish, wallmountable, robust steel construction, glass doors/windows

Mounting Type : Wall mounted

Application : Fire safety, emergency use in buildings, factories, warehouses, public areas

Hose Reel Drum

Hose Reel Drum

Minimum Order Quantity : 1 Piece

Working Temperature : 10C to +60C

Installation Type : Wall Mounted

Features : Corrosion resistant, Heavyduty, Easy installation

Mounting Type : Wall Mount

Application : Fire Fighting

Flexible Pipe

Flexible Pipe

Minimum Order Quantity : 1 Piece

Working Temperature : 20C to +90C

Installation Type : Wall/Floor Mounted, Direct Coupling

Features : Flexible, Durable, Corrosion Resistant, Leakproof, Easy Installation

Mounting Type : Clamp/Bracket Mounted

Application : Plumbing, Gas Connections, Water Supply, Industrial Piping

Single Zone Panel

Single Zone Panel

Minimum Order Quantity : 1 Piece

Working Temperature : 10C to 55C

Installation Type : Wall Mounted

Features : Sounder, Reset key, Test button, LED status indicators

Mounting Type : Surface Mount

Application : Fire Alarm System, Fire Detection



Back to top